| BYPASS
HEAD MODEL 80BX
This
Tri-Rotor pump model has an intergral dashpot
relief valve-in-head. The standard spring can
be set up to 65 PSI at which setting it will bypass
full volume; the heavy duty spring can be set
up to 100 PSI.
TO
ADJUST BYPASS RELIEF PRESSURE
Remove
hexagonal cap (A) and loosen locknut. Turn adjusting
screw (B) in to increase pressure and out to decrease
pressure. With:
Standard Spring, #J324, (min. 10PSI/Max.
65 PSI). Each full turn represents approx. 3 PSI.
Do not exceed 17 total turns.
Heavy Duty Spring, #J531, (Min. 20 PSI/Max.
100 PSI). Each full turn represents approx. 8
PSI. Do not exceed 12 total turns.
Extra Heavy Duty Spring, #J6152, (Min. 40
PSI/Max. 145 PSI). Each full turn represents approx.
15 PSI. Do not exceed 8 total turns.
Tighten
locknut and replace the hexagonal cap, making
sure J328 gaskets are in place.
TO
REVERSE DIRECTION OF ROTATION 80BX
(6 STEPS)
STEP 1: Unbolt bypass head and remove with
bypass head gasket as one unit, making sure gasket
is not damaged.
STEP
2: Unbolt shaft housing and remove together
with rotor group and gasket as one unit.

THIS
LEAVES PUMP IN THREE SECTIONS AS PICTURED.
STEP
3: Turn body "about face" and switch
dowel pins.
STEP
4: Bolt the three sections back together,
making sure the shuttle pin enters the bore of
the shuttle.
STEP
5: To reverse bypass head components- release
spring tension as described above. Remove valve
cage with valve and remove end cap with spring
and adjusting parts. Exchange to opposite sides
of the head and reassemble.
NOTE:
SPRING ADJUSTING SCREW MUST ALWAYS BE ON SUCTION
SIDE OF PUMP. Be sure spring is centered on valve
and adjusting plate.
STEP
: Reverse wiring to run motor in opposite
direction.
SOLID
HEAD MODEL 80B
The
model 80B has a solid head with the shuttle pin
set in a fixed position to give constant volume
for simple transfer service. A RELIEF VALVE SHOULD
BE INSTALLED IN THE DISCHARGE LINE FOR PROTECTION.
TO
REVERSE DIRECTION OF ROTATION 80B
(5 STEPS)

STEP
1: Unbolt solid head and remove with head
gasket as one unit, making sure head gasket is
not damaged.
STEP
2: Unbolt shaft housing and remove together
with rotor group and gasket as one unit.
THIS
LEAVES PUMP IN THREE SECTIONS AS PICTURED.
STEP
3: Turn body "about face" and switch
dowel pins.
STEP
4: Bolt the three sections back together,
making sure the shuttle pin enters the bore of
the shuttle.
STEP
5: Reverse wiring to run motor in opposite
direction. |