| BYPASS
HEAD MODEL 40AX
This
Tri-Rotor pump model has an integral dashpot relief
valve-in-head, The standard spring can be set
up to 50 PSI at which setting it will bypass full
volume; the heavy duty spring can be set up to
100 PSI.
TO
ADJUST BYPASS RELIEF PRESSURE

Remove hexagonal cap (A) and loosen locknut. Turn
adjusting screw (B) in to increase pressure and
out to decrease pressure.
Tighten
locknut and replace hexagonal cap, making sure
copper gaskets are in place.
TO
REVERSE DIRECTION OR ROTATION 40A

The rotation of the 40AX pump may not be reversed
in the field for extended periods of time. The
pump may be run in reverse TEMPORARILY for such
purposes as stripping the lines, etc.
To reverse the direction of rotation, a bypass
head pump of opposite rotation must be ordered
from the factory. See "putting pump into
service" section of Page
1.
SOLID
HEAD MODEL 40A
The
model 40A has a solid head with the shuttle pin
set in a fixed position to give constant volume
for simple transfer service. A RELIEF VALVE SHOULD
BE INSTALLED IN THE DISCHARGE LINE FOR PROTECTION.
TO
REVERSE DIRECTION OF ROTATION 40A

The
rotation of the 40A pump may not be reversed in
the field for extended periods of time. The pump
may be run in reverse TEMPORARILY for such purposes
as stripping the lines, etc.
To reverse the direction of rotation, a solid
head pump of opposite rotation must be ordered
from the factory. See "putting pump into
service on Page 1.
|